How to Wire an Indoor Timer Light Switch

Running pool equipment 24 hours is usually unnecessary and expensive. Installing an Intermatic T timer is a great way to dramatically reduce run time and energy costs. The following steps will provide a guide on how to install the T timer. A T timer is used for V supply voltage. If you are using V supply voltage, you will need a T timer. The installation steps are the same for either. Toggle navigation Menu Cart Call.

To provide the best experience on our website, we require your browser to have JavaScript enabled. Here are the instructions for how to enable JavaScript in your web browser. Once you've enabled Javascript, please refresh this page. Or give us a call at , and we would be happy to take your order by phone. Email Guide. Print Guide. See All Steps. Things You'll Need. T with Metal Enclosure. T with Plastic Enclosure.

Step by Step. Step 1 Open up the T box and remove the black plastic insulator. The insulator is held in place by one screw. Step 2 Locate an area on the wall near the pool equipment for the timer box. Locate the timer out of reach of the sprinklers or drainage spouts. Step 3 Mark the locations for the three mounting screws. One is located on top of the timer box and two are located inside the timer box towards the bottom.

Step 4 Drill three holes where the mounting screws will be installed. Step 5 Install screws or other hardware appropriate for the mounting surface through the mounting holes of the Intermatic T timer box. Hex head anchors are recommended for better traction when installing into concrete. Step 6 Remove two of the knockouts from the timer box. One knockout will lead to the breaker panel and the other will lead to the pool equipment. Step 8 Your next step is to wire the power from the breaker panel to the pool timer.

Incorrect wiring can cause dangerous shocks and may void your warranty. Step 10 Measure the distance from the breaker panel to the timer box. Step 11 Feed the three cables from the breaker panel through the conduit and into the Intermatic timer box. Step 12 Press the conduit into the terminal adapter.

Step 13 Connect the ground wire to the green screw located on the Intermatic timer mechanism. The ground wire will be green or exposed copper. Step 14 Locate the two input power cables that come from the breaker. Connect one to terminal 1 and the other to terminal 3. Terminals 1 and 3 are called the "Lines". It only matters that one cable is on 1 and the other is on 3. Step 15 The next steps will involve connecting the equipment to the timer.

Step 16 Measure the distance from the equipment to the timer box. Step 17 Feed the three cables from the equipment through the conduit and into the Intermatic timer box. Step 18 Press the conduit into the terminal adapter. Step 19 Connect the ground wire to the green screw located on the Intermatic timer mechanism. Step 20 Connect the cables running from the equipment to terminals 2 and 4. One cable will go to teminal 2 and the other to terminal 4. Terminals 2 and 4 are called the "Loads".

The Loads are what the timer controls. Step 21 Place the black plastic insulator back into the box and tighten the screw to keep it in place. Step 22 The next steps will involve programming the timer. This Time Pointer will point directly to the current time. Step 24 To set the time, pull the Intermatic Clock-Dial outward. Turn the dial in either direction and align the exact time of day on the Clock-Dial to the Time Pointer. The picture displays the timer set to Step 25 The next steps will demonstrate how to set the trippers.

The trippers will determine when the equipment will turn on and off. Step 26 Locate the "On" tripper. The "On" tripper is typically green and will be labeled "On". Step 27 To set the "On" tripper, hold the tripper against the desired time and tighten the tripper screw firmly. The picture displays the "On" tripper set at 8: Step 28 Locate the "Off" tripper.

The "Off" tripper is typically gold and will be labeled "Off". Step 29 To set the "Off" tripper, hold the tripper against the desired time and tighten the tripper screw firmly. The picture displays the "Off" tripper set at 4: Step 30 Turn on the the power at the breaker panel. The yellow clock dial should be spinning and the equipment should turn on and off at the set time.

Close the timer door and enjoy the energy savings with using a timer. Add a Comment. The yellow wheel do not spin? The black gear through the large hole is spinning. The timer is advancing and will shut off the equipment with the copper turn off pointer. I have done all the steps as described in this guide. The replacement is part number TM. The yellow wheel was indeed spinning nice and slow.

Thanks all is good now. I have t in metal and plastic. They're excellent - clear, concise. I used them this afternoon, and we're back in business. The GE is discontinued so I bought an Intermatic to replace. When I put the Intermatic in it would not work. Make sure your supply voltage to the timer is V. Check that the input voltage lines are connected to terminals 1 and 3 as shown in Step Lastly, check that the yellow clock disc is engaged.

Pull it out and release it a couple of time to make sure it engages with the timer motor gears. Checked that all is wired according to direction here. Turned back on and pool motor working fine but clock is NOT advancing. As far as I know, there is no way to rewire them to control both levels of voltage. How can I hook up a v item or plug to it? Can I just use one of the v legs coming into the box, but where would my neutral wire go? Obviously the ground wire goes to the ground.

This is a V timer. Both of your supply wires are V and there is no neutral wire. I'm running out teo outlets with Is it possible to wire an additional outlet for ? When the yellow dial rotates, the ON tripper will contact the switch at the time you set and flip it to ON or leave it at ON. Make sure you have both trippers installed and that one is an ON tripper and the other is an OFF tripper. One is longer than the other. Check that you have the correct timer for your voltage.

How to wire Intermatic T and T and T timers. For more wires, or different gauge wires, attach with wire nut and connect jumper wire to screw plate . How to wire T timer. Volt wires going to Load connect to terminals A and 2. . clock motor. How to wire Intermatic pool timer: How to wire pool timers.

Running pool equipment 24 hours is usually unnecessary and expensive. Installing an Intermatic T timer is a great way to dramatically reduce run time and energy costs. The following steps will provide a guide on how to install the T timer. A T timer is used for V supply voltage.

Automatic light switch timers are wired into the mains lighting circuit. However many of the homes in the UK do not have a neutral wire available at the switch.

You can replace any indoor light switch with an indoor timer switch to control any light in your home. Depending on the type of timer switch you choose, you can program it to automatically turn your lights on and off at least once a day.

Wiring Diagrams

Remember Me? Advanced Search. Page 1 of 2 1 2 Last Jump to page: Results 1 to 10 of Brought to you by Carl's Jr. Makes me go Hmmm

Wiring a Timer switch No Neutral Wire

Hi guys I bought a house in south florida that has a Intermatic Mechanical Timer but i want something modern and I wonder if can be done? I think I only have 2 zones if im correct. You definitely have three zones, based on six control pins between 4 and 6 AM three pins turn the system ON, the other three turn it OFF. For example I see that your controller is set to water one of the zones for twice the time of the others, but if there ever been an issue which is very likely whereas power went out due to Florida hurricanes or something similar, in a middle of the cycle, your controller would go out of sync and from than on a wrong zone would get twice the water. It took me about two days to replace a similar timer and four zone indexing valve, professionals can do it in a few hours. Rachio Gen 2 - 8 zone model Waterproof enclosure to install the Rachio unit outdoors Pump start relay in a weatherproof enclosure sized for pump hp and voltage in the system. The power would go to the pump start relay instead of the Intermatic timer. The lead from the Rachio Master Valve terminal would also go to the pump start relay to turn on the pump. Configure the Rachio zones as mentioned in the lead link that Gene and I both linked to.

This piece of equipment can save you a lot of money and use less energy helping you steward your footprint on our planet. As of installing it we were able to cut out 16 hours of use on our Hot Water Heater daily

Browse documentation, including instructions sheets and manuals, for discontinued or obsolete products. Watch How-To instruction videos. Search our new and improved Image Library for images of Intermatic Products.

wiring an intermatic PE153 for 240v pool pump

Search waterheatertimer. Search using. How to wire T timer 40 amp for timer lights, motor, water heater, pump etc. Large image Indoor metal box Buy: T series at Amazon. T at Amazon. Larger image Mechanism only Use thumb spring located top inside timer to remove old mechanism from enclosure Buy: TM at Amazon. Larger image Outdoor metal box Buy: TR at Amazon. Larger image Outdoor plastic box Buy:

Intermatic Programmable Pool Timer Mode Applications

I currently have a manual TR Intermatic time clock for my pool pump. The wiring is quite simple. There are also 2 white wires going from the 2 line in connectors to drive the clock motor. I am now replacing the manual time clock with an Intermatic PE digital timer. This timer has 3 independent circuits. I am only interested in 1 circuit.

Search waterheatertimer. Search using. Large image Indoor metal box Buy: T series at Amazon Resource: T at Amazon. Larger image Mechanism only Buy: TM at Amazon.

You need to tell us what timer model you are using. But if you are dealing with one of the Intermatic timer, the black wire is the wire to the power feed, what you desribe as "black hub. That is the black wire from the "2-wire". White wire of the timer goes to the "white hub. What you explain makes sense as the intructions says if you have now power to switch the Red and black. In this case I thought the black from the right side wire was the power and the black from the black hub was the load.

Posted by 0rlando on Dec 13, Green wire from elec box is connected to green wire to outlet. Posted on Jan 11, Hi there, Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two. Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

It's simple to set up the Intermatic Programmable Pool Timer series 3-circuit timer! Intermatic has seven pre-programmed modes for common pool and spa applications. Just choose the mode that best suits your needs! Each of the three single pole circuits are defined generically, and can control any load within each of its individual circuit ratings. All three circuits act independent of each other. In Mode 1, the Intermatic Programmable Pool Timer Three Circuit Clock Mechanism is ideal for pool or spa only applications where each piece of equipment is independently controlled.

How to set an Intermatic Sprinkler / Instigation Timer